Packaged Ammonia Chillers (R717) | EVAPNEX

R-717 • LOW-CHARGE PACKAGED INDUSTRIAL REFRIGERATION

EVAPNEX Packaged Ammonia Chillers – R717

Industrial Cooling with Natural Refrigerant Ammonia

EVAPNEX offers packaged low-charge ammonia chiller enquiries for food processing, dairy, cold storage, process cooling and industrial refrigeration. The commercial model references below follow proven capacity bands used in current low-charge packaged ammonia equipment. Final compressor selection, refrigerant charge, dimensions, certified performance and supplied manufacturer model are confirmed at quotation.

Request an Ammonia Chiller Quote →

Illustrative packaged air-cooled industrial chiller, not a specific EVAPNEX ammonia model

Illustrative industrial chiller image. Final R717 package appearance depends on the selected manufacturer and capacity.

Reference Package Architecture

  • Natural refrigerant R717 (ammonia) in a low-charge packaged refrigeration configuration.
  • Semi-hermetic screw-compressor platform with variable-speed control in the reference design basis.
  • Air-cooled condenser with variable-speed EC fans for condensing control; oil cooling integrated into the package.
  • Electronic expansion and compressor protection controls with pressure and temperature monitoring.
  • Stainless-steel refrigeration and hydraulic circuit elements in the reference configuration.
  • Packaged electrical and control panel with capacity control and remote monitoring capability, subject to supplier model.
  • Optional heat recovery, variable glycol flow and hydraulic pumping arrangements can be reviewed for the project.

These are configuration features drawn from the technical source you provided and current manufacturer literature for comparable low-charge ammonia chillers. EVAPNEX does not represent these as one fixed construction across every supplier.

Medium-Temperature Glycol Chillers

Selection basis: published reference duty using R717, 35°C ambient and glycol entering/leaving approximately -2 / -8°C. EVAPNEX model numbers are our commercial enquiry references; the capacities and reference package data follow the published equipment range.

EVAPNEX modelCooling capacity kWTotal input kWCondenser fansAirflow m³/hGlycol flow m³/hHydraulic connectionApprox. weight kg
EV-NH3-MT-2502491056 × Ø800114,00038.2DN1003,765
EV-NH3-MT-3203171258 × Ø800160,00048.6DN1255,020
EV-NH3-MT-3703691438 × Ø800182,00056.6DN1255,020
EV-NH3-MT-50049921110 × Ø800228,00076.5DN1506,275
EV-NH3-MT-63563425114 × Ø800320,00097.2DN1508,785
EV-NH3-MT-74073828714 × Ø800320,000113DN1508,785

Low-Temperature Glycol Chillers

Selection basis: published reference duty using R717 with glycol entering/leaving approximately -19 / -25°C.

EVAPNEX modelCooling capacity kWTotal input kWCondenser fansAirflow m³/hGlycol flow m³/hHydraulic connectionApprox. weight kg
EV-NH3-LT-1301311036 × Ø800114,00022.6DN1003,765
EV-NH3-LT-1601601236 × Ø800114,00027.6DN1253,765
EV-NH3-LT-1951931448 × Ø800182,00033.3DN1255,020
EV-NH3-LT-26526220710 × Ø800228,00045.2DN1506,275
EV-NH3-LT-32032024710 × Ø800228,00055.2DN1506,275
EV-NH3-LT-39038728914 × Ø800320,00066.8DN1508,785

Direct-Expansion Ammonia Condensing Units / Chiller Packages

Selection basis: published R717 direct-expansion reference at -30°C evaporating temperature and 35°C ambient.

EVAPNEX modelCooling capacity kWTotal input kWCondenser fansAirflow m³/hLiquid / gas connectionApprox. weight kg
EV-NH3-DX-105106846 × Ø800114,000DN15 / DN653,500
EV-NH3-DX-1301311036 × Ø800114,000DN20 / DN804,300
EV-NH3-DX-1601571188 × Ø800182,000DN20 / DN805,020
EV-NH3-DX-2102121708 × Ø800182,000DN20 / DN1005,400
EV-NH3-DX-26026220510 × Ø800228,000DN20 / DN1006,275
EV-NH3-DX-31531323614 × Ø800320,000DN25 / DN1008,785

For direct-expansion applications, evaporator type, superheat control, oil return, refrigerant charge and local ammonia-safety requirements must be engineered for the complete system.

Typical Applications

Food, Dairy & Beverage

Process chilled water, glycol cooling, cold-storage utilities, production-area cooling and refrigeration duties where ammonia is appropriate to the project and local regulations.

Cold Storage & Industrial Process Cooling

Central glycol systems, low-temperature process loads and refrigeration plants requiring packaged outdoor equipment with reduced refrigerant charge and a compact plant footprint.

Heat-Recovery Projects

Oil heat recovery, condenser heat recovery and hot-water integration can be reviewed where useful heating demand overlaps the refrigeration load.

Replacement & New Projects

New installations and packaged replacements can be reviewed from required cooling duty, glycol conditions, ambient design temperature, available electrical supply and project safety requirements.

What to Send for Selection

  • Required cooling capacity and whether the duty is medium-temperature glycol, low-temperature glycol or direct expansion.
  • Glycol type/concentration and inlet/outlet temperatures, or required evaporating temperature for DX duty.
  • Design outdoor ambient, project country and installation elevation.
  • Electrical supply, allowable current or starting constraints and preferred redundancy.
  • Heat-recovery requirement, if any: hot-water flow and target inlet/outlet temperature.
  • Applicable ammonia safety code, machinery or pressure-vessel requirements, access and installation constraints.

Send your R717 ammonia refrigeration requirement →

Reference capacity data on this page is adapted from the low-charge packaged ammonia chiller technical literature supplied by the user and from current manufacturer literature for the same product family. Final quotations must state the actual supplied manufacturer, model, performance conditions and documentation.