Cooling Tower Replacement Parts Catalogue

COOLING TOWER COMPONENTS • TECHNICAL MATCHING • GLOBAL ENQUIRIES

Cooling Tower Replacement Parts & Brand-Matching Enquiries

Brand-Specific Technical Catalogues

Brentwood AccuPac Fill – Models & Technical Data →

Model and media specifications including CF1200, CF1900, CFS3000, OF21MA, VF19PLUS, VF3800 and XF75, with a link to the Brentwood technical brochure and a quotation route.

Marley Replacement Parts – Models & Technical Data →

Marley fill and eliminators, Geareducer model families, X7 / HP7000 fans, Spiral Target, NS5 / NS7 and NX nozzles, drives and other replacement components.

Find a Replacement by Its Actual Specification

EVAPNEX welcomes enquiries for cooling tower replacement parts used in counterflow, crossflow, induced-draft, forced-draft and closed-circuit equipment. Send us the existing component’s make/model, photos, drawings, dimensions and duty; we can review compatible options and seek availability and pricing from the appropriate source. An OEM name or part number is a useful reference, not proof that a replacement is interchangeable.

Send a Parts Enquiry →

Illustrative FRP cooling tower structural components and grating

Illustrative component image; exact supply, brand, warranty and fit must be confirmed for each quotation.

Fans, Blades & Fan Cylinders

Axial fan assembly for cooling tower applications

Fan Assemblies and Replacement Blades

Axial fan assemblies, individual blades, hubs and fan stacks can be reviewed using fan diameter, blade count, pitch, hub and shaft dimensions, rotation, airflow direction, operating speed, airflow/static-pressure duty and motor rating. Confirm whether the requirement is a direct replacement, an upgrade or a re-engineered fan selection.

For a branded replacement, share the exact original model or part number and photograph of any casting or nameplate.

Read our failed-fan replacement checklist →

Gearboxes, Gear Drives & Mechanical Transmission

Gearbox and Drive Replacement

We can assess enquiries for cooling-tower gear reducers, shafts, couplings and associated drive components. Provide existing gearbox manufacturer, complete type/serial number, ratio, input speed and power, output speed, shaft rotation, input/output shaft geometry, mounting arrangement, lubrication and expected thermal/mechanical duty.

For model-specific enquiries, customers may cite reference families such as Sumitomo Hansen P4, Sumitomo Paramax SFC or Amarillo single-reduction cooling-tower drives. Availability, genuine-origin status, dimensional and duty suitability, warranty and permissible substitution must be verified with the proposed supplier; EVAPNEX does not claim to be an authorised dealer or hold these models in stock.

Enquire About Gearboxes →

Illustrative cooling tower fan drive gearbox

Amarillo Cooling Tower Gearboxes – Model Catalogue

EVAPNEX accepts enquiries for the following Amarillo right-angle fan-drive models, including original-model replacements and A-Series enquiries. Identify the exact model and reduction ratio from the existing gearbox nameplate; the same model family can have multiple ratios and ratings.

Gearbox familyAmarillo model references
Right-angle single reduction65A, 85, 110, 135, 155, 175
Right-angle double reduction1008, 1110, 1311, 1712, 1712.5, 1713A, 1713W, 1814, 2016, GT1712
“A” Series single reduction (Marley replacement family)A20, A22, A27
“A” Series double reduction (Marley replacement family)A32, A34, A36, A38, A40

Manufacturer model datasheets and dimensional drawings: Amarillo Gear model datasheets ↗. Cooling-tower drive and A-Series information ↗.

For quotation: state model, reduction ratio, motor power and speed, output shaft and rotation, shaft dimensions, mounting-foot and bolt-hole dimensions, required quantity and destination. For an A-Series Marley replacement, include the original Marley model and existing installation drawing. Final duty and fit must be checked for the exact selected unit.

Request an Amarillo gearbox quotation →

Fill Media, Drift Eliminators & Air Inlet Louvers

Cooling tower fill media

Water and Airside Internals

Film and splash fill, drift eliminators, louvers and support grids should be matched to the original tower geometry and water/air duty. Share existing dimensions, fill depth, sheet or module arrangement, water temperature and quality, fouling tendency, pressure-drop limits, material and fire-performance requirements where applicable.

For retrofit work, specify whether original fit dimensions must be maintained or revised supports, water distribution and airside performance may be considered.

Nozzles, Spray Systems, Pumps & Water-Level Parts

Distribution and Auxiliary Components

Replacement spray nozzles, headers, distribution troughs, pumps, float valves and make-up-water parts need the current tower layout and hydraulic conditions. Provide material, connection size, number and spacing of outlets, operating pressure, water flow, allowable pressure drop, water quality and required distribution pattern.

Pump enquiries should include flow/head duty, motor electrical details, fluid properties, mounting and connection dimensions.

Cooling tower spray nozzle and water distribution components

Motors, Instrumentation & Safety Components

Cooling tower blade and hub assembly

Electrical and Monitoring Replacement Parts

Motor and control enquiries should include electrical supply, rated power/current, speed, frame, mounting, protection class, insulation and control method. Vibration switches, temperature or level instruments and other safety devices require the existing model, setpoints, approvals, wiring/interface information and installation conditions.

FRP, Fan Stacks, Gratings & Tower Hardware

Structural and Casing Parts

FRP fan stacks, panels, gratings, pultruded profiles, access parts, fasteners and tower hardware may be assessed against the original dimensions, loading, chemical and UV exposure, operating temperature and mounting details. Structural replacements must meet the relevant engineering and site safety requirements; a visually similar component is not sufficient proof of suitability.

Illustrative FRP cooling tower fan stack

Brand and OEM Cross-Reference Enquiries

EVAPNEX sources and supplies cooling tower replacement components identified by their original manufacturer, model and technical specifications. Send the exact brand and part number when known; we will review the requested original part or an appropriate alternative against the dimensional and operating requirements.

The names Sumitomo, Hansen, Paramax, Amarillo and TUF-LITE refer to third-party products or product families and are used only to identify customer replacement requirements. EVAPNEX is not represented here as an authorised seller or affiliated company; supply route and brand authenticity must be confirmed before quotation.

Cooling Tower Parts by Brand and Product Family

Browse all principal replacement categories below, not only gearboxes. We source components by existing make and model or by a technically matched specification. Provide an existing part number, photos and drawings; we will check the specific offered construction and availability.

Fan Assemblies and Blades

Cooling tower and air-cooled exchanger fan references for new and replacement assemblies.

Brand or familyProduct referencesTechnical matching data
TUF-LITE II3000, 3000H, 3000HC low-noise, 6000H, 6000MH, 7000 seriesDiameter, fan curve, blade count, hub details, rotation, RPM and motor power.
Howden PROD, E, FPX and SX seriesDiameter, airflow and static pressure, blade and hub arrangement, rotation and sound limit.
Axial fan sparesBlades, hubs, complete fan assembliesOriginal blade/hub identification, bore, fan pitch, balancing and installation envelope.

Drive Shafts and Couplings

Complete motor-to-gearbox transmission and composite shaft assemblies.

Brand or familyProduct referencesTechnical matching data
Addax / Rexnord AddaxLRA, LRF, LRR; examples LRA350.275, LRA485.338, LRF450.275 and LRR650.625Full suffix, shaft length, flange bolt patterns, speed and transmitted torque.
Amarillo shaftsCF67, CF73, CF83; examples CF67 425L, CF73 800X and CF83 950XExact suffix, span, flange and shaft dimensions, alignment and operating RPM.
Transmission sparesFlexible couplings, shim packs, hubs and hardwareShaft diameter, bolt pattern, torque, permissible misalignment and material.

Film and Splash Fill Media

Replacement selection depends on fouling, temperature, water loading, tower arrangement and dimensions.

Brand or familyProduct referencesTechnical matching data
Brentwood AccuPacCF1900 cross-fluted film fill; OF21MA low-fouling fill; VF-19 PLUS vertical-fluted fillPack size and flute orientation, water quality, material, duty and operating temperature.
Brentwood splash fillHTP25 modular splash, Kelly Bar and TurboSplashBar and support geometry, length, water loading and available fill height.
C.E. ShepherdCES-190 film fill; V-Bar splash fillModule dimensions, profile, mounting/support layout and water quality.
Tower ComponentsOpti-Bar and Opti-Grid splash fillProfile dimensions, support span and installation arrangement.
Other fill optionsHybrid, high-efficiency, mechanically assembled and site-assembled fillTower cell geometry, fouling, duty, material and current fill construction.

Nozzles and Water Distribution

Spray-water components for crossflow and counterflow cooling towers.

Brand or familyProduct referencesTechnical matching data
C.E. ShepherdCrown, Target, Square Pattern and Quick Change Orifice (QCO) familiesOrifice, distribution pattern, deck-hole/pipe connection, flow and water pressure.
General counterflow sprayFull cone, umbrella, threaded and grommet-mounted nozzlesNozzle spacing, connection size, pressure, water quality and material.
Distribution systemHeaders, laterals, troughs, adapters and spray platesExisting layout drawings, number of outlets, pressure and total water flow.

Fan Stacks and FRP Tower Parts

Replacement structural items need dimensional, loading and mounting confirmation.

Brand or familyProduct referencesTechnical matching data
Dyna-Fab fan stacks6 ft, 10 ft, 14 ft and 18 ft height referencesFan throat and discharge diameter, overall height and mounting flange.
FRP fan stacksFan cylinders, custom FRP stacks and panelsTower model, bolt circle, tip clearance, site wind and access requirements.
FRP profiles and hardwareGratings, square/rectangular tubes, pultrusions, stainless or galvanised fixingsSection dimension, material, load, fastener grade and existing drawings.

Motors, Pumps and Instrumentation

Mechanical, hydraulic and electrical matching for auxiliary tower equipment.

Brand or familyProduct referencesTechnical matching data
Fan-drive motorsCooling tower motors and replacement motorsPower, frame, voltage, phase, frequency, RPM, IP class and control method.
Monitoring componentsVibration switches and level/temperature sensorsExisting model, setpoint, output, supply, approval and mounting.
Water circuit accessoriesSpray pumps, make-up valves, strainers and basin-level accessoriesFlow/head, connection size, material, fluid and electrical supply.
Air/water managementDrift eliminators, air inlet louvers and support modulesModule dimensions, material, air path, drainage and mounting details.

Visual Parts Directory – Request by Name or Reference

The following product names and reference styles are used in enquiries for different cooling-tower makes. Share your actual tower model or component part number to establish dimensions, materials and compatibility. The category photographs are illustrative, not model-by-model product photographs; the parts you receive will match the confirmed quotation.

If the original brand or model is known, enter it in your enquiry. Where an exact OEM item is requested, specify whether an original branded part or a technically matched replacement is required.

Fill media

Illustrative Fill media category, exact item may differ

VF610-LC / VF610-LC-style film fill

Enquire about this part →

Crossflow fill packs

Enquire about this part →

Trickle-fill PP net fill

Enquire about this part →

CF750-LC / cross-fluted fill

Enquire about this part →

CF-style film fill

Enquire about this part →

Counterflow fill packs

Enquire about this part →

BAC-style PVC fill media

Enquire about this part →

Brentwood-style splash-bar fill

Enquire about this part →

PP grid / splash fill

Enquire about this part →

Stainless-steel fill assemblies

Enquire about this part →

Round cooling tower fill

Enquire about this part →

Low-fouling and high-temperature fill

Enquire about this part →

Drift eliminators

Illustrative Drift eliminators category, exact item may differ

Hamon-type drift eliminator

Enquire about this part →

Evapco-type drift eliminator

Enquire about this part →

Kingsun drift eliminator

Enquire about this part →

Marley-type eliminator

Enquire about this part →

Liang Chi-type drift eliminator

Enquire about this part →

Blade/profile and modular packs

Enquire about this part →

Fan motors and drive units

Illustrative Fan motors and drive units category, exact item may differ

Direct-drive permanent-magnet motors

Enquire about this part →

Liang Chi-type fan motors

Enquire about this part →

ABB industrial fan motors

Enquire about this part →

Siemens fan motors

Enquire about this part →

WEG cooling tower motors

Enquire about this part →

Cast-iron cooling-tower motors

Enquire about this part →

Aluminium-shell fan motors

Enquire about this part →

Reduced-speed / belt-drive motors

Enquire about this part →

Air inlet louvers

Illustrative Air inlet louvers category, exact item may differ

Plastic air inlet louver panels

Enquire about this part →

Corrosion-resistant FRP louvers

Enquire about this part →

Long-profile cooling tower inlet louvers

Enquire about this part →

FRP moulded louver grilles

Enquire about this part →

PVC inlet louver media

Enquire about this part →

FRP and plastic accessories

Illustrative FRP and plastic accessories category, exact item may differ

FRP fill support grating

Enquire about this part →

FRP walkway and structural grating

Enquire about this part →

FRP moulded boards

Enquire about this part →

FRP moulded spray pans

Enquire about this part →

FRP tower wall panels

Enquire about this part →

Float and make-up water valves

Enquire about this part →

Water distributor hubs

Enquire about this part →

ABS / nylon rope knots and fasteners

Enquire about this part →

Pultruded profiles, handrails and brackets

Enquire about this part →

Cooling tower spray nozzles

Illustrative Cooling tower spray nozzles category, exact item may differ

BAC-type crossflow nozzle

Enquire about this part →

Industrial water-distribution nozzle

Enquire about this part →

Evapco-type replacement spray nozzle

Enquire about this part →

Plastic rotating sprinkler nozzle

Enquire about this part →

Kingsun-type ABS nozzle

Enquire about this part →

Marley NS6-type nozzle

Enquire about this part →

Hamon-type PVC nozzle

Enquire about this part →

Marley-type ABS cooling tower nozzle

Enquire about this part →

Hamon-type ABS target nozzle

Enquire about this part →

Triple-splash ABS nozzle

Enquire about this part →

Stainless-steel tower nozzle

Enquire about this part →

Hot-deck target nozzle

Enquire about this part →

General ABS cooling-tower nozzle

Enquire about this part →

Reflection-pattern nozzle

Enquire about this part →

Triple-splash industrial spray nozzle

Enquire about this part →

Sprinkler heads and distribution hubs

Illustrative Sprinkler heads and distribution hubs category, exact item may differ

ABS cooling tower sprinkler head

Enquire about this part →

Aluminium cooling tower sprinkler head

Enquire about this part →

Rotary water distribution head

Enquire about this part →

Replacement spray-head bushings and fittings

Enquire about this part →

What to Send for a Technical Match

  • Photos of the component and complete nameplate, brand, model and part number, if available.
  • Cooling tower or fluid-cooler make/model, application and site country.
  • Original drawings, component dimensions, mounting and connection details.
  • Operating duty and water or ambient conditions relevant to the component.
  • Required quantity, whether a like-for-like OEM part or technically reviewed alternative is acceptable, and any mandatory approval or certification.

A technical cross-reference is a review step, not confirmation of identical fit, performance, origin, warranty or availability. We verify those conditions for each proposed supply.

Submit Your Cooling Tower Parts Requirement →